VI Series Water Savers with Internal Water Restraining System
Single-stage liquid ring vacuum pumps with valves in close coupled version with mechanical seal
→ page with U.S. Units
|
Performance data |
|
| Max. suction capacity |
between 2.2 m³/h and 55 m³/h |
| Min. inlet pressure |
down to 33 mbar |
| Possible media |
dry and humidified gases |
| Sound pressure level |
65 - 68 db(A) at 80 mbar |
|
Temperature of operational liquid |
up to 80 °C |
|
Temperature of absorbed gas |
up to 120 °C |
| Design |
single-stage pumps in inverted design with valves and internal water restraining system
 ATEX approval for the entire series: device group II, equipment category 2G, type of protection IIB, temperature class T4 |
| Motor |
0.12 - 2.2 kW / 0.16 - 3.0 HP AC / three-phase motors |
| Materials |
non-ferrous metal / stainless steel |
| Connections |
G 1/4 to G 1 |
| Shaft sealing |
mechanical seal |
| Dimensions |
refer to brochure |
| Weight |
refer to brochure |
| Advantages |
- water saving: at suction pressures < 600 mbar, the water can be completely retained in the pump
- low noise due to optimized hydraulics and separation
- low calcification risk and easy temperature control possible
- easy disassembly due to inverted design and
O-ring sealing |
| Possible applications |
- extruder degasification
- sterilization of surgical instruments, textiles and beds (steam and gas sterilization)
- evacuation in central vacuum systems
|
| 50 Hz data |
| Type |
Speed [rpm] |
Suction capacity [m³/h] |
Min. inlet pressure [mbar] |
| VI 2 |
2850 |
2.2 |
45 |
| VI 8 |
2850 |
9.5 |
40 |
| VI 18 |
2850 |
18 |
40 |
| VI 25 |
2850 |
24 |
40 |
| VI 30 |
2850 |
27 |
33 |
| VI 55 |
2850 |
46 |
33 |
| 60 Hz data |
| Type |
Speed [rpm] |
Suction capacity [m³/h] |
Min. inlet pressure [mbar] |
| VI 2 |
3450 |
2.4 |
45 |
| VI 8 |
3450 |
11.4 |
40 |
| VI 18 |
3450 |
22 |
40 |
| VI 25 |
3450 |
29 |
40 |
| VI 30 |
3450 |
33 |
33 |
| VI 55 |
3450 |
55 |
33 | |
Contact |
|