VI Series
Water Savers with Internal Water Restraining System

Single-stage liquid ring vacuum pumps with valves
in close coupled version with mechanical seal

page with U.S. Units

Performance data

 
Max. suction capacity

between 2.2 m³/h and 55 m³/h

Min. inlet pressure

down to 33 mbar

Possible media

dry and humidified gases

Sound pressure level

65 - 68 db(A) at 80 mbar

Temperature of
operational liquid

up to 80 °C

Temperature of
absorbed gas

up to 120 °C

Design

single-stage pumps in inverted design with valves and internal water restraining system
ATEX
ATEX approval for the entire series:
device group II, equipment category 2G,
type of protection IIB, temperature class T4

Motor

0.12 - 2.2 kW / 0.16 - 3.0 HP
AC / three-phase motors

Materials

non-ferrous metal / stainless steel

Connections

G 1/4 to G 1

Shaft sealing

mechanical seal

Dimensions

refer to brochure

Weight

refer to brochure


Advantages 
  • water saving: at suction pressures < 600 mbar, the water can be completely retained in the pump
  • low noise due to optimized hydraulics and separation
  • low calcification risk and easy temperature control possible 
  • easy disassembly due to inverted design and
    O-ring sealing

Possible applications
  • extruder degasification 
  • sterilization of surgical instruments, textiles and beds (steam and gas sterilization)
  • evacuation in central vacuum systems

 

50 Hz data
 Type Speed 
[rpm]
Suction
capacity
[m³/h]

Min. inlet
pressure
[mbar]

 VI 2 2850 2.2 45
 VI 8 2850 9.5 40
 VI 18 2850 18 40
 VI 25 2850 24 40
 VI 30 2850 27 33
 VI 55 2850 46 33

 

60 Hz data
 Type Speed 
[rpm]
Suction
capacity
[m³/h]

Min. inlet
pressure
[mbar]

 VI 2 3450 2.4 45
 VI 8 3450 11.4 40
 VI 18 3450 22 40
 VI 25 3450 29 40
 VI 30 3450 33 33
 VI 55 3450 55 33